Sign In
Upload
Manuals
Brands
Bryant Manuals
Heat Pump
548J*14D Series
Bryant 548J*14D Series Manuals
Manuals and User Guides for Bryant 548J*14D Series. We have
3
Bryant 548J*14D Series manuals available for free PDF download: Installation Instructions Manual, Submittal Data
Bryant 548J*14D Series Installation Instructions Manual (56 pages)
SINGLE PACKAGE ROOFTOP HEAT PUMP SIZE 14 with PURONR (R--410A) REFRIGERANT
Brand:
Bryant
| Category:
Heat Pump
| Size: 7.93 MB
Table of Contents
Table of Contents
1
Theinstallation.
3
Safety Considerations
3
Rated Indoor Airflow (Cfm)
4
Refrigeration System Components
7
Installation
9
Jobsite Survey
9
Step 1 - Plan for Unit Location
9
Roof Mount
9
Step 2 - Plan for Sequence of Unit Installation
9
Curb- - Mounted Installation
9
Pad- - Mounted Installation
9
Frame- - Mounted Installation
9
Step 3 - Inspect Unit
9
Step 4 - Provide Unit Support
9
Slab Mount (Horizontal Units Only)
11
Alternate Unit Support (in Lieu of Curb or Slab Mount)
11
Step 5 - Field Fabricate Ductwork
11
For Units with Accessory Electric Heaters
11
Step 6 - Rig and Place Unit
11
Positioning on Curb
11
Step 7 - Convert to Horizontal and Connect
12
Ductwork
12
Step 8 - Install Outside Air Hood
12
Economizer Hood Removal and Setup
12
Factory Option
12
Two Position Damper Hood Removal and Setup
13
Factory Option
13
Economizer Hood and Two- - Position Hood
13
Step 9 - - Install External Condensate Trap and Line
14
Step 10 - Make Electrical Connections
15
Field Power Supply
15
All Units
16
Units Without Factory- - Installed
19
Non- - Fused Disconnect
19
Units with Factory- - Installed
19
Convenience Outlets
19
Factory- - Option Thru- - Base Connections
21
Units Without Thru- - Base Connections
21
Field Control Wiring
21
Thermostat
21
Central Terminal Board
22
Commercial Defrost Control
22
Unit Without Thru- - Base Conversion Kit
24
Heat Anticipator Settings
24
Electric Heaters
24
Single Point Boxes
25
Heater and Supplementary Fuses
25
Heater Low- - Voltage Control Connections
25
Speed Indoor Fan Motor System with Variable
26
Economi$Er R X (Factory- -Installed Option)
27
Product Description
27
System Components
27
Specifications
27
W7220 Economizer Module
27
Electrical
27
Inputs
27
Outputs
28
Environmental
28
S- - Bus Sensor Wiring
28
CO 2 Sensor Wiring
29
Interface Overview
29
User Interface
29
Keypad
29
Menu Structure
30
Setup and Configuration
30
Time- - out and Screensaver
30
Sequence of Operation
36
Enthalpy Settings
40
Two- -Speed Fan Operation
40
Checkout
41
Power up
41
Initial Menu Display
41
Power Loss (Outage or Brownout)
41
Status
41
Checkout Tests
41
Troubleshooting
41
Alarms
41
Clearing Alarms
41
RTU Open Controller System
42
Supply Air Temperature (SAT) Sensor
44
Outdoor Air Temperature (OAT) Sensor
44
Economi$Er 2
45
Field Connections
45
Space Temperature (SPT) Sensors
45
Indoor Air Quality (CO 2) Sensor
46
Outdoor Air Quality Sensor
47
Space Relative Humidity Sensor
47
Smoke Detector/Fire Shutdown (FSD)
47
Connecting Discrete Inputs
47
Communication Wiring - - Protocols
48
General
48
Local Access
49
RTU Open Controller Troubleshooting
49
Outdoor Air Enthalpy Control
50
Differential Enthalpy Control
50
Return Air Enthalpy Sensor
50
Smoke Detectors
51
Step 11 - Adjust Factory- -Installed Options
52
Step 12 - Install Accessories
52
Step 13 - Check Belt Tension
52
Unit Start- - up Checklist
55
Advertisement
Bryant 548J*14D Series Installation Instructions Manual (36 pages)
SINGLE PACKAGE ROOFTOP HEAT PUMP WITH WITH PURON (R-410A) REFRIGERANT
Brand:
Bryant
| Category:
Heat Pump
| Size: 8.79 MB
Table of Contents
Table of Contents
1
Safety Considerations
2
Safety Considerations
4
Installation
4
Jobsite Survey
4
Step 1 - Plan for Unit Location
4
Roof Mount
5
Step 2 - Plan for Sequence of Unit Installation
5
Curb- - Mount Installation
5
Pad- - Mount Installation
5
Frame- - Mount Installation
5
Step 3 - Inspect Unit
5
Step 4 - Provide Unit Support
5
Roof Curb Mount
5
Slab Mount (Horizontal Units Only)
5
Alternate Unit Support
5
Step 5 - Field Fabricate Ductwork
7
For Units with Accessory Electric Heaters
7
Step 6 - Rig and Place Unit
7
Step 7 - - Convert to Horizontal & Connect Ductwork
8
Step 8 - Install Outside Air Hood
8
Economizer Hood Removal and Setup
8
Two Position Damper Hood Removal and Setup
9
Economizer Hood and Two- - Position Hood
10
Step 9 - - Install External Condensate Trap and Line
10
Step 10 - Make Electrical Connections
11
Field Power Supply
11
Units Without Factory- - Installed Disconnect
13
Units with Factory- - Installed Disconnect
13
Convenience Outlets
13
Factory- - Option Thru- - Base Connections
15
Units Without Thru- - Base Connections
15
Field Control Wiring
15
Thermostat
15
Unit Without Thru- - Base Conversion Kit
16
Heat Anticipator Settings
16
Electric Heaters
16
Single Point Boxes
17
Heater Low- - Voltage Control Connections
17
Outdoor Air Enthalpy Control
18
Differential Enthalpy Control
18
Return Air Enthalpy Sensor
18
RTU- - MP Control System
19
Supply Air Temperature (SAT) Sensor
21
Outdoor Air Temperature (OAT) Sensor
22
Economi$Er2
22
Field Connections
22
Space Temperature (SPT) Sensors
22
Economizer Controls
23
Indoor Air Quality (CO 2 ) Sensor
23
Outdoor Air Quality Sensor
24
Connecting Discrete Inputs
24
Communication Wiring - - Protocols
25
General
25
Local Access
25
RTU- - MP Troubleshooting
25
Smoke Detectors
27
System
27
Controller
27
Sensor
27
Smoke Detector Locations
28
Supply Air
28
Return Air Without Economizer
28
Return Air with Economizer
28
Step 11 - - Adjust Factory- - Installed Options
32
Step 12 - Install Accessories
33
Bryant 548J*14D Series Submittal Data (12 pages)
548J***D Single Package Rooftop Heat Pump Units With Field-Installed Electric Heat Sizes 08-14 With Puron (R-410a) Refrigerant
Brand:
Bryant
| Category:
Heat Pump
| Size: 1.31 MB
Table of Contents
Standard Features
1
Performance Data
2
Electrical Data
2
Field Installed Accessories
4
Advertisement
Advertisement
Related Products
Bryant 548J*12D
Bryant 548J*17 D Series
Bryant 548J*17 Series
Bryant 548J*09D
Bryant 548J*08D
Bryant 548J*24 D Series
Bryant 548J A Series
Bryant 548J-04A
Bryant 548J-06A
Bryant 548J-07A
Bryant Categories
Furnace
Air Conditioner
Heat Pump
Thermostat
Fan
More Bryant Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL