REPLACEMENT PARTS LIST

CLEAN-UP OF BROKEN LAMPS
(see warnings on page 3 of this manual)
UV lamps contain a small amount of mercury, like a typical fl uorescent lamp. DO NOT touch any of the mercury
with your bare hands.
1. While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass
with your hands.
2. Vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all lamp
material.
3. Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag.
4. Check with your local waste management authority for local disposal or recycling requirements.
According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into household
waste.
5. Wash hands, and remove and wash clothes for added safety measures.
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the Duo-2000 Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
P/N 46638600 09/18 Rev E
Replacement Part Number
46636300
625001003
730118175
80213041175
For replacement parts, contact Field Controls at:
Phone: 252-522-3031 • Fax: 252-522-0214
Email: sales@fi eldcontrols.com
18" Lamp Assy Duo
120/240V Rep Ballast Assy
Carbon, Duo-2000
Pro-Cell Honeycomb 4.125 x 17.625
Page 10 of 12