Fleck 5600 Econominder Owner's Manual
Hide thumbs Also See for 5600 Econominder:

Advertisement

Quick Links

5600 / 5600 Econominder
Owner's Manual
For questions or in case of emergency, please call
your local service technician (preferably the one who
installed the system).

Advertisement

loading

Summary of Contents for Fleck 5600 Econominder

  • Page 1 5600 / 5600 Econominder Owner’s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system).
  • Page 2 Product Features, Benefits, & Job Specification Sheet Congratulations on the purchase of your new water treatment system with the 5600 control valve. You will have peace of mind knowing your system will bring you years of treated water use and enjoyment. Product Features &...
  • Page 3 To manually regenerate the valve, turn the manual regeneration knob clockwise until it reads “REGEN.” 5600 Econominder Model Setting the Time of Day: To set the time of day, push the red button and spin the 24-hour gear until the present time of day is visible above the time of day arrow.
  • Page 4 Descriptions of Softener & Filter Control Valve Positions Service: Hard water enters unit at valve inlet and flows down through the mineral in the mineral tank. Conditioned water enters center tube through the bottom distributor, then flows up through the center tube, around the piston, and out the outlet of the valve.
  • Page 5 General Residential Checklist & Troubleshooting Adding Salt Ensure that the salt level in the brine tank is always above the water line. Water Pressure Water pressure range of 20-125 psi is required for regeneration valve to operate effectively. Electrical Facilities An uninterrupted alternating current (A/C) supply is required.
  • Page 6 5600 Time Clock & Econominder Models 5600 Time Clock 5600 Econominder...
  • Page 7 5600 L-Style Econominder & Time Clock Models 5600 L-Style Econominder 5600 L-Style Time Clock...
  • Page 8 To Download the Service Manual for this Valve, please visit: www.fleckcontrols.com P/N 42447 Rev. A 6/07...

This manual is also suitable for:

5600