Electrical Connection; General Information - Winterhalter UC-S Installation Instructions Manual

Connecting competitors' dosing units to

Advertisement

5.

Electrical connection

5.1

General information

In the separating wall to the electrical installation space, you will find a drawing of the transfer strip for the
dosing equipment.
The current draw on the transfer strip must not exceed 0.5 A. A higher current draw could trigger the
upstream 4.0 A control-circuit fuse, as the sum of all connected actuators could otherwise exceed the
permitted maximum continuous current.
The transfer strip can be assigned various signals depending on how parameter P 704 is set.
Table 1: Transfer strip terminal assignment for UC-S, UC-M, UC-L, UC-XL
Terminal strip X3
L1
N
PE
WASH
FILL
How to make parameter P 704 accessible:
 Tap the following buttons in turn:
Winterhalter Gastronom GmbH; Winterhalterstrasse 2-12, 88074 Meckenbeuren; Tel.: 07542-402-0Issued: 12-2016
When mains power switch is turned on, the control phase is applied here
When mains power switch is turned on, the neutral potential is applied
here
Protective earth (green-yellow)
Depending on the setting for parameter P704 (see table below)
Type in "1575"
INFO
Incorrectly entered digits
can be corrected with the
 button.
 Using the scroll buttons (1), set the value of parameter
P704.
 Press the button (2) to save your input.
 Press the back button (3) to exit from the menu.