5.
Electrical connection
5.1
General information
In the separating wall to the electrical installation space, you will find a drawing of the transfer strip for the
dosing equipment.
The current draw on the transfer strip must not exceed 0.5 A. A higher current draw could trigger the
upstream 4.0 A control-circuit fuse, as the sum of all connected actuators could otherwise exceed the
permitted maximum continuous current.
The transfer strip can be assigned various signals depending on how parameter P 704 is set.
Table 1: Transfer strip terminal assignment for UC-S, UC-M, UC-L, UC-XL
Terminal strip X3
L1
N
PE
WASH
FILL
How to make parameter P 704 accessible:
Tap the following buttons in turn:
Winterhalter Gastronom GmbH; Winterhalterstrasse 2-12, 88074 Meckenbeuren; Tel.: 07542-402-0Issued: 12-2016
When mains power switch is turned on, the control phase is applied here
When mains power switch is turned on, the neutral potential is applied
here
Protective earth (green-yellow)
Depending on the setting for parameter P704 (see table below)
Type in "1575"
INFO
Incorrectly entered digits
can be corrected with the
button.
Using the scroll buttons (1), set the value of parameter
P704.
Press the button (2) to save your input.
Press the back button (3) to exit from the menu.
Explanation