15.4 Connecting the drain hose

 The hose may not be shortened or damaged.
 Do not bend the hose when laying it.
Caution
The drain hose is located in the machine.
INFO
The machine is equipped with a drain pump. The on-site water drain must have a trap. The maxi-
mum height of the on-site water drain is 650 mm.
Back view

16 Electrical connection

Danger to life. Live components.
 The machine and the relevant additional devices must be connected by an electrical compa-
ny authorised by the relevant electricity supplier as per the locally applicable standards and
Danger
regulations.
 When performing installation and maintenance work, unplug the machine from the power
network. Check that there is no voltage.
IMPORTANT
Observe the connection diagram for detailed information.
 The electrical safety of this machine is guaranteed only if it is connected to a correctly installed protective
circuit and a residual current circuit breaker. It is very important that this basic safety requirement is test-
ed and in case of doubt the house installation is checked by a qualified electrician.
 The circuit diagram must be observed.
 The electrical connection of the machine must correspond with the data of the rating plate.
 A fixed connection must as a priority be installed for machines that are delivered without a plug.
 When the machine is connected permanently (without a plug), a mains disconnector with all-pole separa-
tion from the network must be installed. The mains disconnector switch must have a contact opening
width of at least 3 mm, and must also be lockable in the neutral position. The installation site must be
near the machine and easily accessible.
 The electrical connection must be secured as a separately fused circuit with slow fuses or circuit break-
ers. The protection depends on the total power consumption of the machine. The total connected load is
specified on the rating plate of the machine.
 Install a residual current circuit breaker in the electrical supply line.

16.1 Requirements for the mains cable

 Cable type: Type H07 RN-F or equivalent
 The wires must be fitted with wire end ferrules.
 Cross section and number of cores: suitable for on-site power and protection
for more information see the sticker in the front panel

16.2 Establishing an earth connection

 Connect the machine into the equipotential bonding system.
INFO
The terminal screw is located behind the right rear leg of the machine. It is identified with the
symbol.
 Connect the drain hose (A) to the machine.
 Connect the drain hose to the on-site water drain.
Electrical connection