4.6.2

Network configuration

4.6.2.1

Interfaces

Note
IPv4 addresses and netmask according to RFC 1918
The factory-set IPv4 addresses and netmasks can be changed as required, but must keep to
the specification RFC 1918.
Note
So that the SINEMA RC can be reached via the Internet router, on the router, port forwarding
needs to be set up for the following ports:
• For the WBM, see Web server settings (Page 52).
– for HTTPS TCP port 443 (preset, can be changed)
• For the establishment of the OpenVPN tunnel, see OpenVPN settings (Page 99)
– the UDP port 1194 (preset, can be changed)
– the TCP port 5443 (preset, can be changed)
• For the certificate update the TCP port 6220 (fallback port preset, can be changed)
• For the establishment of the IPsec VPN tunnel
– UDP port 500 (cannot be changed) and UDP port 4500 (cannot be changed)
– IP protocol ESP (layer 3 protocol)
Calling the Web page
In the navigation, select "System > Network configuration" and the "Interfaces" tab.