3.1.4.2 Automatic Reboot Mode
The following parameters are available only when the WebRelay is set to Automatic Reboot relay
mode.
Ping IP Address
This is the IP address that WebRelay will ping. This is typically the IP address of the device that will be
re-booted upon failure (such as a server, router, computer, etc.). It could however, be the address of a
device on the opposite side of a communications link. This is useful to auto reboot communications
devices such as CSU/DSUs, satellite modems, routers, etc.
Successful Ping Period
This is the time interval (in seconds) between successful ping requests. This time can be set from 1 to
6000 seconds (100 minutes or 1.67 hours).