6. Technische Daten

Operating voltage:
Frequency
Power consumption: max
Standby min
Max switching capacity.
Switching capacity
Min. switching capacity
Gap
Protection rating
Protection class
Operating temperature
Power reserve
Rated impulse voltage
Pollution degree
Contact
Max. switching cycles with 16 A resistive
load
Incandescent lamp load
Halogen lamp load
Energy-saving lamp
Fluorescent lamps (LLB low-loss bal-
lasts):
uncorrected
series-corrected
parallel-corrected
Fluorescent lamps (EB – electronic
ballasts)
Mercury and sodium vapour lamps
parallel-compensated
Compact fluorescent lamps (EB)
LED-lamps (<2 W)
LED-lamps (>2 W < 8 W)
LED-lamps (>8 W)
Contact material
Switch output
Corresponds to type 1 BSTU in
accordance with IEC/EN 60730-2-7 or
IEC/EN 60730-1
SELV switching is not permitted.
Switching of any external conductor is
permitted.
230–240 V AC +10 % / –15 %
50–60 Hz
0,4 W
0,4 W
16 A (at 250 V AC, cos ϕ = 1)
4 A (at 250 V AC, cos ϕ = 0,6)
10 mA/230 V AC
100mA/24 V AC/DC
<3 mm
IP 20 in accordance with
EN 60529
II in accordance with
EN 60730-1 subject to
designated installation
–25 °C ... +55 °C
10 years at +20 °C
4 kV
2
NO contact µ
50 000
2000 W
2000 W
300 W
2000 VA
2000 VA
1300 W (140 µF)
1200 W
730 VA (80 µF)
300 W
55 W
180 W
200 W
AgSnO2 + tungsten prerun
contact
phase independent
7. Contact
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Tel. +49 7474 692-0
Fax ++49 7474 692-150
Hotline
Tel. +49 7474 692-369
hotline@theben.de