RIO Status Example

The following example illustrates an M1 status file example. It
shows a typical M1 file and the G file used to configure the scanner.
There are no inhibited devices specified in the M0 file (not shown).
Notice that:
M1:e.8 is an image of word 1 (primary/normal logical device
address) of the G file.
M1:e.3 is an image of word 3 (complementary logical device
address) of the G file.
M1:e.9 is an image/copy of word 2 (primary/normal logical
device size) of the G file.
M1:e.4 is an image/copy of word 4 (complementary logical
device size) of the G file.
The three quarter logical rack device located in logical rack 3
(M1:e.9/13) is not active. The fault is indicated by the Enabled
Device Fault status bit, bit 0, word 0 (M1:e.0/0).
The three quarter logical rack device located in logical rack 11
(M1:e.4/13) is not active. The fault is indicated by the Enabled
Device Fault status bit, bit 0, word 0 (M1:e.0/0).
Because the device at M1:e.8/13 is faulted, bit 13 of word 10
(M1:e.10/13) is 0. M1:e.15/1 through M1:e.15/3, which
correspond to M1:e.9/13 through M1:e.9/15 are also set to 1,
indicating a problem with the device in logical rack 3.
Because the device at M1:e.3/13 is faulted, bit 13 of word 5
(M1:e.5/13) is 0. M1:e.15/5 through M1:e.15/7, which
correspond to M1:e.4/13 through M1:e.4/15 are also set to 1,
indicating a problem with the device in logical rack 11.
M1 (Status) File Primary/Normal
15
14
13
12
11
x
x
x
x
x
x
x
x
x
x
RIO Logical
Rack 3
0
0
1
0
0
1
1
1
0
0
0
0
0
0
0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
e = slot number of the SLC rack containing the scanner
x = not used/defined
G File
RIO Logical Rack 3
Starting Group
6
4
2
0
6
0
0
1
0
0
1
1
1
0
0
Scanner Configuration and Programming
10
9
8
7
6
5
x
x
x
x
x
x
x
x
x
x
x
x
RIO Logical
RIO Logical
Rack 2
Rack 1
0
1
0
0
0
0
1
1
0
1
1
1
0
1
0
0
0
0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
RIO Logical Rack 2
RIO Logical Rack 1
Starting Group
Starting Group
4
2
0
6
4
2
0
1
0
0
0
0
1
1
0
1
1
1
4–27
4
3
2
1
0
M1 File
x
x
x
1
1
M1:e.0
x
x
x
0
1
M1:e.2
RIO Logical
Rack 0
1
1
0
0
1
M1:e.8
1
1
0
0
1
M1:e.9
1
1
0
0
1
M1:e.10
x
0
0
0
0
M1:e.12
x
0
0
0
0
M1:e.13
x
0
0
0
0
M1:e.14
x
1
1
1
0
M1:e.15
RIO Logical Rack 0
Starting Group
0
6
4
2
0
1
1
0
0
1
1
1
0
0
1
Publication 1747 6.6 - July 1996

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents