SERVICE INSTRUCTION
EN
SI-2-25-28-G (OUTSIDE):SI-2-25-28-E (OUTSIDE) 12/4/14 1:35 PM Page 1
PACKING REPLACEMENT

PACKING REPLACEMENT INSTRUCTIONS

NOTE 1:
JGV-463 Packing Replacement Instructions
2 piece packing covered by U.S. Patent No. 5,209,501.
Other patents pending.
www.carlisleft.com
NOTE 2:
SI-2-25-28-G (OUTSIDE):SI-2-25-28-E (OUTSIDE) 12/4/14 1:35 PM Page 3
KK-4987-2 GUN REPAIR KIT
(FOR JGA, JGV, JGHV, JGP, JGPV, LMG, MSA, MSV, & PGA GUNS)
INSTRUCTIONS
Service Instruction
SI-2-25-28-G
Replaces SI-2-25-28-F
KK-4987-2 Gun Repair Kit
(for JGA, JGV, JGHV, JGP, JGPV, LMG,
MSA, MSV, & PGA GUNS)
1. Remove adjusting knob, needle spring, spring pad,
and needle from gun.
2. Loosen packing nut and remove.
3. Remove old packing. See disassembly illustration
below.
4. Assemble packing nut to needle.
5. Assemble packing in order shown to needle.
6. Insert needle all the way into gun body seating in tip.
7. Install needle spring, spring pad, and adjusting knob.
8. Thread packing nut into gun body.
9. Tighten packing nut in equal increments - no more
than 1/6 turn at a time.
10. After each adjustment, pull needle open and observe
needle closure.
11. If needle snaps shut, continue adjusting nut until
there is evidence of needle bind or slow closing.
12. Back off packing nut 1/12 turn to the point where
needle snaps shut. Packing nut must remain tight
enough to prevent loosening by hand.
13. Pull needle several times to verify needle snaps shut
and check packing nut for looseness.
1 / 4
SI-2-25-28-R1 (7/2018)
ANGLED SIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KK-4987-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for DeVilbiss KK-4987-2

  • Page 1 SI-2-25-28-G (OUTSIDE):SI-2-25-28-E (OUTSIDE) 12/4/14 1:35 PM Page 3 Service Instruction SI-2-25-28-G Replaces SI-2-25-28-F KK-4987-2 GUN REPAIR KIT KK-4987-2 Gun Repair Kit (for JGA, JGV, JGHV, JGP, JGPV, LMG, MSA, MSV, & PGA GUNS) (FOR JGA, JGV, JGHV, JGP, JGPV, LMG, MSA, MSV, & PGA GUNS)
  • Page 2 2) remove fluid needle to the State of California to cause cancer and adjusting screw to relieve spring pressure. birth defects or other reproductive harm. DeVilbiss Sales and Service Listing: www.devilbiss.com www.carlisleft.com 2 / 4 SI-2-25-28-R1 (7/2018)
  • Page 3 TYPICAL EXPLODED VIEW Use AV-1 copper gasket only on model shown. Do not use with plastic baffle or threaded baffle. GUN MODELS (SEE STAMP ON SIDE OF GUN HANDLE) TYPE JGA JGA-510, (JGA-503) JGA-502 JGHV-530 JGHV-531 MODEL JGV (REPLACE- JGP, TYPE MSA (JGV-560, (MSA-501/503)
  • Page 4 For specific warranty information please contact Carlisle Fluid Technologies. Carlisle Fluid Technologies is a global leader in innovative finishing technologies. Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice. DeVilbiss , Ransburg , ms , BGK , and Binks ®...

Table of Contents