Hardware Lookup Table Panel

© National Instruments Corporation
Signal Source—You can specify the input source for the CSYNC
signal as either channel 0, channel 1, channel 2, channel 3, or
external.
Frame—For externally synchronized, line scan, or area scan
cameras, this pop-up menu allows you to extend the frame
acquisition timeout period. This setting is used during acquisition
only if External Lock Mode is the current selection.
Color Mode—The color mode pop-up menu allows you to select a
color acquisition of the red, green, and blue planes if using an RGB
camera. RGB Color Camera mode uses channels 1, 2, and 3 to
acquire the red, green, and blue color planes. You must be in one of
the external modes to perform an RGB color camera acquisition.
The video is synchronized on the channel configured in the basic
configuration panel. Grab is disabled while in RGB Color Camera
mode.
Save Settings—Click on this button to save the current settings to
your camera file.
You can configure the input lookup table (LUT) to implement simple
imaging operations such as contrast enhancement, data inversion,
gamma manipulation, or other nonlinear transfer function. Figure 5-14
shows the Hardware Lookup Table panel settings.
5-17
Chapter 5
Configuration Utility
PCI-1408/NI-IMAQ for Mac OS