Combustion settings.

This allows for adjustment of the "pellet" quan-
tity and the "air flow"
Pellet
This feature allows the user to increase or
decrease by 25% the pellet quantity during the
start-up and power process. Press "set". The
display starts to flash. Press "+" or "-" to
increase or decrease (between -10 to +10), as
required. Each unit must be multiplied by 2.5 to
obtain the correct percentage.
Air
This feature allows the user to increase or
decrease by 25% the rotation speed of the
fume extractor during the start-up and power
stages. Press "set". The display starts to
flash. Press the "+" or "-" key to increase or
decrease (from -10 to
+10), as required. Each unit must be multiplied
by 2.5 to obtain the correct percentage. Press
"ok" to confirm.
Technical menu,
The technical menu is password protected, the
password is only provided to authorised techni-
cians.

Operation.

Start up.
After loading the pellets into the hopper , press
and hold the ON/OFF button for 3 seconds, to
start the stove. During the lighting phase, the
display will show the message "Ignition" (until
this phase is completed.
The pellets are fed through the supply channel
to the burning pot (combustion chamber),
where they will be ignited using an igniter. This
process may take 5 to 10 minutes, depending
on whether the worm screw used to push
through the pellets has been previously filled or
not. Once the ignition phase is completed, the
message "On" appears on the display. The
heating power can be adjusted at any time by
pressing the power selection button for approx-
imately 1 second. You can select from the five
pre-set power levels that are available. The
selected power is indicated on the display. The
initial power status at each start-up will corre-
spond to the power level set before the last
stop.
Note Before starting the machine check that
the baffle plate is correctly positioned.
Shut down.
To turn off the pellet stove is carried out by
pressing the ON / OFF button for 3 seconds.
The display will show "shut down" until full
completion of this phase. The extractor will
operate until the fume temperature of 64ºC is
reached, to guarantee that all the material has
been burnt.
Note
Do not shut down the appliance by isolat-
ing the electrical supply .
Fig 10 shows the baffle position as viewed
from inside the firebox. Item 1 on the picture
highlights that the tab on the baffle must over-
lap down over the vermiculite lining at the rear
of the firebox. Item 2 shows the gap to the
front between the baffle and the body of the
appliance, this should be approx 20mm
CO ALARM
The fitting of CO Alarms in the same room as the
appliance is a compulsory requirement under cur-
rent Building Regulations. For ROI an additional
CO Alarm must be fitted either inside each bed-
room or within 5 metres of the bedroom door, refer
to Building Regulations Part J. Further guidance on
the installation of a carbon monoxide alarm is
available in BS EN 50292:2002 and from the alarm
manufacturers instructions.