MCi Reliability Driven Series Operator's Manual page 89

Table of Contents

Advertisement

SPN
FMI
3599
3
3599
4
3599
4
3606
9
3609
3
3609
4
3610
2
3610
3
3610
4
3659
3
3659
4
3659
6
3660
3
3660
4
3660
6
3661
3
3661
4
3661
6
3662
3
3662
4
3662
6
3663
3
3663
4
3663
6
3664
3
3664
4
3664
6
3695
9
3695
13
3695
14
3695
19
3696
9
3696
13
3696
14
3696
19
3711
31
3713
31
3716
31
3719
0
3719
15
3719
16
3719
31
3720
15
3936
18
4041
0
4041
9
4041
16
4077
0
4077
3
4077
4
July 2015
DD13 DIAGNOSTIC CODES
CODE DESCRIPTION
MCM Internal Injector Power Supply Failed High
High Side Digital Output 3 Circuit Failed Low
MCM Internal Injector Power Supply Failed Low
J1939 ESS Message is missing
DOC Inlet Pressure Circuit Failed High
DOC Inlet Pressure Circuit Failed Low
DPF Outlet Pressure Sensor - Not Plausible
DPF Outlet Pressure Circuit Failed High
DPF Outlet Pressure Circuit Failed Low
Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MAX)
Injector Cylinder #1 Amplifier Control Valve Abnormal Operation (MIN)
Injector Cylinder #1 Amplifier Control Valve, Valve Shorted Circuit
Injector Cylinder #2 Amplifier Control Valve Abnormal Operation (MAX)
Injector Cylinder #2 Amplifier Control Valve Abnormal Operation (MIN)
Injector Cylinder #2 Amplifier Control Valve, Valve Shorted Circuit
Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (MAX)
Injector Cylinder #3 Amplifier Control Valve Abnormal Operation (MIN)
Injector Cylinder #3 Amplifier Control Valve, Valve Shorted Circuit
Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (MAX)
Injector Cylinder #4 Amplifier Control Valve Abnormal Operation (MIN)
Injector Cylinder #4 Amplifier Control Valve, Valve Shorted Circuit
Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (MAX)
Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (MIN)
Injector Cylinder #5 Amplifier Control Valve, Valve Shorted Circuit
Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (MAX)
Injector Cylinder #6 Amplifier Control Valve Abnormal Operation (MIN)
Injector Cylinder #6 Amplifier Control Valve, Valve Shorted Circuit
DPF Regen Inhibit MUX Switch Message Stopped Arriving
DPF Regen Inhibit MUX Switch Message Contains SNV Indicator
DPF Regen Inhibit MUX Switch Message Not Received this Ignition Cycle
DPF Regen Inhibit MUX Switch Message Contains Data Error Indicator
DPF Regen Force MUX Switch Message Stopped Arriving
DPF Regen Force MUX Switch Message Contains SNV Indicator
DPF Regen Force MUX Switch Message Not Received this ignition Cycle
DPF Regen Force MUX Switch Message Contains Data Error Indicator
Parked Regen Failed - DOC Temp In Low Preventing Dosing
Parked Regen Failed - DOC Temp Out, Not Reaching Target Temp
High Idle Regen - Low Temperature
Soot Level Very High
DPF Zone 3 Condition
Soot Level High
DPF Zone 2 Condition
DPF Ash Clean Request
DPF Pressure - Out of Range Low
20ms ECU OS Task Locked in an Endless Loop
20ms ECU OS Task Timed out Prior to Completion
1000ms ECU OS Task Locked in an Endless Loop
Doser Fuel Line Pressure High
Doser Fuel Line Pressure Sensor Circuit Failed High
Doser Fuel Line Pressure Sensor Circuit Failed Low
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

J4500

Table of Contents