SPN
FMI
2798
4
2900
9
3031
2
3031
3
3031
4
3056
2
3057
2
3216
2
3216
3
3216
4
3216
13
3216
21
3226
2
3226
3
3226
4
3226
13
3226
21
3236
9
3242
3
3242
4
3242
8
3242
20
3246
0
3246
3
3246
4
3246
8
3246
15
3246
20
3246
21
3250
0
3250
3
3250
4
3250
8
3250
14
3250
15
3250
20
3250
31
3251
0
3251
2
3251
16
3361
0
3361
1
3361
3
3361
4
3361
5
3361
7
3363
0
3363
1
3363
3
3363
4
July 2015
DD13 DIAGNOSTIC CODES
CODE DESCRIPTION
Injector Needle Control Valve Cylinder 4, 5, 6 Shorted to Ground
J1939 ETC7 Message is missing
DEF Tank Temperature - Drift
DEF Tank Temperature Sensor Circuit Failed High
DEF Tank Temperature Sensor Circuit Failed Low
SCR Inlet Nox Sensor - Error
SCR Outlet Nox Sensor - Error
SCR Inlet Nox Sensor - Drift
SCR Inlet Nox Sensor Circuit Failed High
SCR Inlet Nox Sensor Circuit Failed Low
SCR Inlet Nox Sensor Signal Not Available
SCR Inlet Nox Sensor - Drift (Low Box)
SCR Outlet Nox Sensor - Drift
SCR Outlet Nox Sensor Circuit Failed High
SCR Outlet Nox Sensor Circuit Failed Low
SCR Outlet Nox Sensor Signal Not Available
Nox Outlet Sensor Drift High
Exhaust Mass Signal Not Available via CAN
DOC Inlet Temperature Circuit Failed High
DOC Inlet Temperature Circuit Failed Low
DOC Inlet Temperature - Signal Spike
DOC Temperature Drift - Inlet High or Outlet Low
DPF Outlet Temperature - Very High
DPF Oulet Temperature Circuit Failed High
DPF Oulet Temperature Circuit Failed Low
DPF Outlet Temperature - Signal Spike
DPF Outlet Temperature - High
DPF Outlet/SCR Inlet Temperature - Abnormal
DPF Outlet Temperature Sensor - Not Plausible
DOC Outlet Temperature - Very High
DOC Outlet Temperature Circuit Failed High
DOC Outlet Temperature Circuit Failed Low
DOC Outlet Temperature - Signal Spike
Abnormal DOC Temperature Rise 2
DOC Outlet Temperature - High
DOC Temperature Drift - Inlet Low or Outlet High
Abnormal DOC Temperature Rise
DPF Pressure - Out of Range Very High
DOC Inlet Pressure Sensor - Not Plausible
DPF Pressure - Out of Range High
DEF Pressure Duty Cycle High
DEF Pressure Duty Cycle Low
DEF Dosing Valve Circuit Failed High
DEF Dosing Valve Circuit Failed Low
DEF Dosing Valve Circuit Failed Open
DEF Unit - Unable to clear Restriction
DEF Tank Temperature - High
DEF Tank Temperature - Low
DEF Coolant Valve Circuit Failed High
DEF Coolant Valve Circuit Failed Low