Installation Operation and Maintenance Instructions
Electrical
WARNING
!
SHOCK HAZARD — Electrical Grounding Required. Never
attempt to repair or perform maintenance on the unit until
the electricity has been disconnected.
Never remove the round grounding prong from the plug
and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing power
plug, or direct wiring can cause serious injury, fire, loss of
property and/or life, and will void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded
(three-prong), polarized receptacle that has been placed
by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz,
15A power supply (normal household current). An individual,
properly grounded branch circuit or circuit breaker is
recommended. A GFCI (ground fault circuit interrupter) is
usually not required for fixed location appliances and is not
recommended for your unit because it could be prone to
nuisance tripping. However, be sure to consult your local codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Cutout Dimensions
PREPARE SITE
Your U-Line product has been designed for either free-standing
or built-in installation. When built-in, your unit does not require
additional air space for top, sides, or rear. However, the front
grille must NOT be obstructed, and clearance is required for an
electrical connection in the rear.
CAUTION
!
Unit can NOT be installed behind a closed cabinet door.
CUTOUT DIMENSIONS
34-1/4"
(87 0 mm)
to
35"
(889 mm)
5
Preferred location
for water line and
eletrical outlet is in
adjacent cabinet.
24"
(610 mm)
5/8"
(16 mm)
7"
(178
mm)
4"
(102 mm)
15-1/4"
(38 7 mm)