E2K-210-05-18 Rev. 3
Setting Position Limits for
STEP 2:
OPEN Valve Position
1
LOCAL
Turn the selector knob to the LOCAL position. At the "OPEN VALVE THEN SELECT STOP" prompt, depress the
declutch lever while rotating the handwheel until the clutch is fully engaged. Release the lever.
When the valve is fully opened. Return the selector knob to the STOP position.
At the "SAVE LIMITS" prompt, select "YES."
Advance to the "SAVE CHANGES?" prompt and answer YES to save the changes.