Quick-Start Guide
E2K-210-05-18 Rev. 3
Setting Position Limits for
STEP 2:
OPEN Valve Position
1
LOCAL
Turn the selector knob to the "LOCAL" position. Hold the control knob in the "OPEN" position until
desired position is reached. Dis-engage motor drive by setting the declutch lever in "HAND" mode. Using
handwheel, move the valve in the close direction for one handwheel turn to allow for motor coasting. Re-
engage motor drive by setting the declutch lever out of "HAND" mode.
Return the selector knob to the "STOP" position. Select "YES" to set new open limit.
Setting Position Limits for Electrical Operation
Setting Position Limits for Electrical Operation
Electrical
2
OPEN
Hold until
desired
position is
reached.
Operation
3
STOP
September 2018
4
YES
5