58
en | Operating
6.3.2
Resetting the Device to Factory Default
1.
2.
3.
4.
5.
The AMC2-4W now has the following network configuration:
–
–
–
–
Figure 6.3: Resetting the AMC2 to delivery state
2018-09 | AMC2-4W_UL |
Reset the AMC2-4W as described above.
Open the upper case of the AMC2-4W as described in
Opening the Case, page 25.
Set all six DIL switches of the RS-485 selector to ON as
shown in the figure below.
Press the reset button on the the board.
Set the DIL switches back in the address state before
resetting.
DHCP = 1
IP = [assigned by DHCP server or "0.0.0.0" if not available]
Subnet mask = [assigned by DHCP server or "0.0.0.0" if not
available]
Password = no password
AMC2 Modular
Controller
Bosch Access Systems GmbH