Mark a 10.5" x 10.5" square around the center mark (inside dimensions). Cut and frame the exterior wall to accept
the wall thimble. Install the wall thimble, on the inside of the exterior wall shield using wood screws.
Attach the venting to the termination using sheet metal screws, for 2 Ply Aluminum Flex installations Inca Metal
Cutting's termination part shall be used and when using Simpson Dura-Vent, Security Venting, ICC or Metal-Fab
consult your local supplier for part numbers.
To install the termination attach the 5" exhaust to the termination and fasten with 3 #8 x ½" hex head sheet metal
screws then attach the 8" vent to the termination and fasten with 4 #8 x ½" hex head sheet metal screws, be sure
that the flex vent overlaps the termination collars a minimum of 2". Then attach the termination to the exterior wall
using four wood screws through the holes in the corner of the vent terminal.
The next step is to apply a bead of mil-pac or RTV 106 to top of the 5" exhaust collar on the unit and attach the 8"
vent using screws (as described above), finally apply a bead of mil-pac or RTV 106 to top of the 8" vent and attach
(as described above).
Safety Cage /
Cage de sécurité
A safety cage may be required on low terminations. Please check with your local safety authority.
Une cage de sécurité peut être nécessaire de faibles terminaisons. S'il vous plaît vérifiez auprès de votre
autorité de sécurité locale.
13.50"
13.50"
10.50"
10.50"
10.50"
10.50"
10.5 x 10.5 MIN OPENING
10.5 x 10.5 MIN OPENING
VIEW OF SAFETY CAGE
Ø 10.00"
Ø 10.00"
"
"
Ø 8.00"
Ø 8.00"
.
.
13
13
50
50
OUTER PIPE 8"
OUTER PIPE 8"
WALL THIMBLE 10"
WALL THIMBLE 10"
Page 31 of 55