USE OF SEALANT
Sealant is required on vent system joints (figure 7), except Metal-Fab Sure-Seal direct vent system joints.
On longer vent runs, especially vertical runs, sealant will ensure that the combustion air enters from
outdoors, and not through the vent joints. Use high temperature sealant, available from local suppliers,
on the inner pipe joint, applying the sealant around the outside of the male part of the vent. A bead of
silicone should be used on the outside of the joint after assembly to seal the supply air. If the venting is
disconnected for servicing, be sure to follow above instructions for resealing venting when reconnecting
A minimum clearance to combustibles must be maintained around the vent pipe of 1" on
Un dégagement minimum aux matériaux combustibles doit être maintenu autour du tuyau
de 1 "sur toutes les canalisations horizontales et verticales fonctionne
to system.
FIGURE 7
VENT RESTRICTOR INSTALLATION
VENT RESTRICTOR
To fasten the Restrictor Plate to the ceiling of the firebox:
1/. Remove the 2 screws that are in place
2/. Align holes in the Restrictor that match the required degree of restriction
3/. Fasten Restrictor Plate back in place.
all horizontal and vertical pipe runs
Apply RTV high temperature
sealant around male pipe.
Vent Configuration Restrictor Size
SEE PAGE 28
SEE PAGE 28
SEE PAGE 28
Restrictor plate
60%
40%
20%
Page 29 of 55