6 Settings
Tab.34
Menu #TIME .DAY
Parameters
HOURS
MINUTE
DAY
DATE
MONTH
YEAR
SUM.TIME
Tab.35
Menu #HYBRID
Parameter
HYBRID ENABLED
COST HIGH TARIFF
(1)
COST LOW TARIFF
(1)
COST GAS/OIL
(1)
BOIL.EFFICIENCY
(1)
COEF.CO2.E.HEAT
(2)
COEF.CO2.E.DHW
(2)
COEF.CO2.GAS.OIL
(2)
(1) The parameter is only displayed if HYBRID ENABLED is set to COST
(2) The parameter is only displayed if the HYBRID ENABLED parameter is set to CO2
6.2

User settings

40
200 ASL HYBRID
Description
Hours.
Can be set from 0 to 23.
Minutes.
Can be set from 0 to 59.
Day of the week.
Can be set from Monday to Sunday.
The day's date.
Can be set from 1 to 31.
Month.
Can be set from January to December.
Year.
Can be set from 2014 to 2099.
AUTO :
Automatic switch to summer time on the last Sunday in
March
Automatic switch to winter time on the last Sunday in
October
MANU :
For countries where the time change is done on other
dates or is not in use
Description
NO : The hybrid control system is not activated.
COST : The hybrid control system optimises run­
ning according to energy costs.
PRIM.EN : The hybrid control system optimises
running according to primary energy consump­
tion.
CO2 : The hybrid control system optimises run­
ning according to the quantity of CO
Cost of peak time electricity.
Cost of off-peak electricity. The tariff is only fac­
tored in if the E.BL parameter is set to PEAK/OFF-
PEAK and the contact BL input is closed.
Cost of fossil energy (oil or gas) (Price of fossil en­
ergy (oil or gas) per litre or m
Efficiency of the boiler connected as back-up.
Coefficient of carbon gas emissions from the heat
pump in heating mode
Coefficient of carbon gas emissions from the heat
pump in domestic hot water mode
Coefficient of carbon gas emissions from the gas /
oil boiler.
Lists of user settings and parameters available in the user manual:
#TIME .DAY menu - User Level
#HYBRID Menu - User Level
emitted.
2
3
)
Setting the Set Point Temperatures
Factory setting
AUTO
Factory setting
Customer setting
NO
€ 0.13
€ 0.09
€ 0.90
1
0.18
0.04
0.23