9-3. Auto Restart Function

This indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with
the set operating conditions in the event of a power supply being accidentally shut down.
The operation will resume without warning three minutes after power is restored.
This function is not set to work when shipped from the factory. Therefore it is necessary to set it to work.

9-3-1. How to Set the Auto Restart Function

To set the auto restart function, proceed as follows:
The power supply to the unit must be on ; the function will not set if the power is off.
Press the [OPERATION] button located in the display of the indoor unit continuously for three seconds.
The unit receives the signal and beeps three times.
The unit then restarts operating automatically in the event of power supply being accidentally shut down.
• When the unit is standby (Not operating)
Operation
Press [OPERATION] button for more than
three seconds. (Less than 10 seconds)
• When the unit is in operation
Operation
Press [OPERATION] button for more than
three seconds. (Less than 10 seconds)
• While the filter check indicator is on, OPERATION button has the function of filter reset betton.
The unit is on standby.
The unit starts to operate.
After approx. three seconds,
The unit beeps three times
and continues to operate.
If the unit is not required to operate at this time, press [OPERATION]
button once more or use the remote control to turn it off.
The unit is in operation.
The unit stops operating.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, press [OPERATION] button
once more or use the remote control to turn it on.
- 47 -
FILE NO. SVM-18048
Motions
The operation indicator is on.
The operation indicator flashes
for 5 seconds.
Motions
The operation indicator is on.
The operation indicator is turned off.
The operation indicator flashes
for 5 seconds.