Indoor Fan Motor Control - Toshiba RAS-B10U2FVG-E Service Manual

Air- conditioners split type
Hide thumbs Also See for RAS-B10U2FVG-E:
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
TA-Tsc
[ °C ]
+2.5
a
+2.0
b
+1.5
+1.0
c
d
+0.5
e
Tsc
(table 1) Indoor fan air flow rate <Cooling>
Fan speed
RAS-B10U2FVG
level
Cool
Fan speed
(rpm)
WF
530
WE
UH
530
WD
H
500
WC
M+
450
WB
450
400
WA
M
W9
360
W8
L+
350
W7
L
300
L−
W6
260
W5
UL
260
W4
240
W3
SUL
240
W2
240
W1
240
Operation flow and applicable data, etc.
MANUAL
Indication
Fan speed
L
L+
(L + M) / 2
M
M+
(M + H) / 2
H
*3 : Fan speed = (M + −L) x 3/4 + L
Fan speed
Hi Power
*4 : Fan speed = (M + −L) x 2/4 + L
H+(WD)
M+(WC)
*5 : Fan speed = (M + −L) x 1/4 + L
*6
*3
(Linear appro ximation
from M+ and L)
*4
*7
*6 : Fan speed = (H −L+) x 3/4 + L+
*8
*5
*7 : Fan speed = (H −L+) x 2/4 + L+
L(W7)
L+(W8)
*8 : Fan speed = (H −L+) x 1/4 + L+
(Linear appro ximation
from H and L+)
RAS-B13U2FVG
Series
Series
Air flow rate
Fan speed
(m3/h)
(rpm)
498
560
498
560
468
540
414
490
414
490
366
440
324
390
315
390
258
340
216
270
216
270
198
250
198
240
198
240
198
240
(Fig. 1)
Hi-POWER
W7
W8
(L + M) / 2
WA
WC
(M + H) / 2
WD
WE
(Fig. 2)
RAS-B18U2FVG
Series
Air flow rate
Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
528
650
624
528
650
624
510
630
600
459
560
528
459
560
528
408
500
468
354
450
414
354
450
414
300
400
366
228
360
324
228
340
300
210
320
282
198
300
258
198
300
258
198
300
258
- 28 -
FILE NO. SVM-18048
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents