Item
To separate using of remote control for each indoor
16. Remote-A or B
selection
unit in case of 2 air conditioner are installed nearly.
Remote Control B Setup.
1. Push and hold
Control by the tip of the pencil.
"00" will be shown on the display (Picture 1).
2. Press
on the display and "00" will disappear and the
air conditioner will turn OFF. The Remote
Control B is memorized
Note : 1. Repeat above step to reset Remote Control
Unit B setup.
Press and hold MODE button for more than 20
seconds.
When A setup changed to B setup : 5 beeps will
sound and operation lamp blinks for 5 seconds.
When B setup changed to A setup : 5 beep will
sound.
Operation flow and applicable data, etc.
button on the Remote
during pushing
(Picture 2).
to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
1. Purpose
This operation is to operate only one
indoor unit using one remote controller.
2. Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
. "B" will show
nearby rooms, this operation prevents the
remote controll signal from being
received simultaneously by both units,
thus preventing both units from operating.
3. Operation
The indoor unit on which the remote
controll selection has been set to B
receives the signal of the remote control
also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)