Indoor Fan Motor Control - Toshiba RAS-B05E2KVG-E Service Manual

Hide thumbs Also See for RAS-B05E2KVG-E:
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ °C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Fan speed level
Mode
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WC)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4
*4 : Fan speed = (M + –L) x 2/4 + L
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W7)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-B05E2KVG-E
Cooling
Dry
Fan speed
Air flow rate
3
(rpm)
m
/hr
500
1200
1200
500
UH
1160
480
1110
H
467
M+
960
388
M
870
340
800
304
L+
750
275
600
190
L
550
170
L-
500
147
UL
500
147
SUL
500
147
500
147
500
147
(Fig. 1)
Fan speed
W7
(L + M) / 2
WA
(M + H) / 2
WD
(Fig. 2)
Heating
Fan speed
Air flow rate
Fan speed
3
(rpm)
m
/hr
(rpm)
480
1160
1200
1160
480
1200
1100
462
1200
383
950
1150
870
340
1000
800
304
900
275
750
800
600
190
750
550
170
620
500
147
500
147
500
500
500
147
500
500
147
500
147
500
500
147
500
500
- 38 -
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
RAS-B07E2KVG-E
Cooling
Heating
Air flow rate
Fan speed
Air flow rate
3
m
/hr
(rpm)
m
500
1200
500
1200
500
1150
1000
489
408
900
350
800
304
750
275
620
200
550
147
500
147
500
147
500
147
500
147
500
147
500
3
/hr
500
500
489
408
350
304
275
200
170
147
147
147
147
147
147