INTRODUCTION Thank you for purchasing this CLARKE Submersible Sewage Cutter Pump. The pump is fitted with a tungsten carbide cutter, and is especially suited for heavily polluted water containing waste solids, such as sewage, light slurry etc. This pump is NOT designed for pumping heavy slurry, sludge, mud, salt water, or any water containing chemicals or other acidic contaminants.
SAFETY INSTRUCTIONS GENERAL PUMP SPECIFIC 1. Read all instructions before use 1. Do not pump explosive / and save these instructions for flammable liquids or chemicals. future use. 2. Never allow the pump to run dry 2. An approved residual current or operate out of the water.
GREEN wire must be connected to the terminal which is marked E or or coloured green. HSEC651A must be connected to a protected 110V supply, through a suitably approved connector. On no account must a 230V, 13amp plug be used.
1. Using the adaptor if required, connect a suitable hose (not supplied) to the pump outlet. • Suitable hoses are available from your local Clarke dealer. 2. Place the pump vertically on a flat surface in the area that you want to drain.
Page 6
• You can adjust the position at which the float switch lead is held to the pump. Adjusting the length of the float switch lead will change the depth of water at which the pump will turn on or off. 5.
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED, ENSURE THE CIRCUIT BREAKER IS OPEN. This pump should require no maintenance other than regular cleaning. If the pump starts to show signs of wear or damage, contact your CLARKE dealer for advice. CLEANING 1.
7. Water level too low - float switch in OFF position - lift float to check switch. 8. If the pump still fails to start, consult your CLARKE dealer for advice. PUMP WILL 1. Check that the inlet is not blocked.