2

Product Specific Information

A. Appliance Certification
MODEL: PRIMO48, PRIMO48ST
PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance
STANDARD: ANSI Z21.50-2016 • CSA 2.22-2016
This product is listed to ANSI standards for "Vented Gas
Fireplaces" and applicable sections of "Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles", and "Gas Fired Appliances for Use at
High Altitudes".
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A HEAT SOURCE.
This appliance is decorative in nature and not intended to be
a source of heat.
NOT FOR USE WITH SOLID FUEL.
This appliance is not intended to burn solid fuel.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
6
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner's Manual • 2310-971 Rev. o • 1/19
B. Glass Specifications
The firebox glass and barrier glass on this appliance are
tempered glass. Hearth & Home Technologies applianc-
es manufactured with tempered glass may be installed
in hazardous locations such as bathtub enclosures as
defined by the Consumer Product Safety Commission
(CPSC). The tempered glass has been tested and cer-
tified to the requirements of ANSI Z97.1 and CPSC 16
CFR 1202 (Safety Glazing Certification Council SGCC#
1595 and 1597. Architectural Testing, Inc. Reports 02-
31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 "Certification and labeling requirements"
which refers to 15 U.S. Code (USC) 2063 stating "...Such
certificate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered."
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specifications
Models
(U.S. or Canada)
PRIMO48
(0-2000 FT)
(NG)
PRIMO48
(0-2000 FT)
(Propane)
PRIMO48ST
(0-2000 FT)
(NG)
PRIMO48ST
(0-2000 FT)
(Propane)
PRIMO60
(0-2000 FT)
(NG)
PRIMO60
(0-2000 FT)
(Propane)
PRIMO60ST
(0-2000 FT)
(NG)
PRIMO60ST
(0-2000 FT)
(Propane)
PRIMO72
(0-2000 FT)
(NG)
PRIMO72ST
(0-2000 FT)
(NG)
Minimum
Orifice
Maximum
Input
Size
Input BTU/h
BTU/h
(DMS)
45,000
31,000
#30
45,000
33,000
#47
45,000
31,000
#30
45,000
33,000
#47
55,000
38,000
#26
50,000
35,000
#45
55,000
38,000
#26
50,000
35,000
#45
61,000
41,000
#23
61,000
41,000
#23