14

Troubleshooting

HBS 300, HBS 200 sensor troubleshooting
Malfunction
Cause
No power at the
breaker has tripped; light switch is in
sensor
OFF position
short circuit
Lights do not switch
light level setting is in nighttime
ON
mode during daytime operation
lamp burned out
power is off
detection zone not correctly adjusted
Lights do not switch
abundant heat from the fixture is
OFF
within detection zone and keeps
lights on as a result of temperature
change
Lights keep
the fixture is moving from side to side
switching ON/OFF
Lights switch ON
HVAC vent is causing air flow to
without obvious
switch lights on
movement
Wireless communication troubleshooting
• Is the receiver device too far away from the transmitting device, resulting in too weak
of a signal at the receiver? (See Transmission Range on page 3.)
• Can the radio signal leave the transmitter and reach the receiver or is it inhibited by
interference (metal enclosure, etc.)
• Is there any possible interference from other transmitters operating on the same
frequency?
• Are any other transmitters operating outside the system which, although working on
a different frequency, are doing so at very high transmission power (ham radio etc.)?
www.autani.com
Remedy
reset breaker, turn light switch
to ON position, check wiring
with voltage tester
check for proper wiring
connections
adjust light level setting
replace lamp
turn power on at circuit breaker
readjust
readjust zone or apply shroud
stabilize the fixture
redirect air flow away from the
sensor

Warranty

HBS 200, HBS 300
STEINEL America warrants its products
against defects in material or workmanship
for a period of five years. STEINEL will
replace or repair the item provided that
it has not been altered or subjected to
abuse, accident, improper installation or
improper use. There are no obligations
or liabilities on the part of STEINEL for
consequential damages arising out of or
in connection with the use or performance
of this product or other indirect damages
with respect to loss of property, revenue,
or profit, or cost of removal, installation or
reinstallation.
HBS-DC Certifications
Complies with UL 508 Standards
FCC ID: V8NHBS1000173
IC: 7737A-HBS1000173
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
conditions:
(1) this device may not cause harmful
interference
(2) this device must accept any interference
received including interference that may cause
undesired operation
(3) Changes or modifications not expressly
approved by the party responsible for
compliance could void the user's authority to
operate the equipment
This equipment complies with the FCC RF
radiation exposure limits set forth for an
uncontrolled environment. This equipment
should be installed and operated with a minimum
distance of 20 centimeters between the radiator
and your body.
HBS-DC
Autani warrants that Autani Products
will be free from defects in materials
and workmanship and conform to its
Specifications for a specified, fixed period
commencing on its date of shipment
and continuing for five (5) years, except
the fixed period for Autani Software,
Managers, and any Autani Product not
installed and commissioned by Autani or
its factory authorized representatives shall
be for one (1) year (the "Warranty Period"),
unless otherwise specified. During the
warranty period, if an Autani Product
does not function substantially according
to its Specification, Autani will either 1)
make it do so or 2) replace it with one
that is at least functionally equivalent. If
Autani is not able to make the warranted
product substantially conform with its
specifications, Buyer may return it to
Autani and the amount paid to Autani
for such product will be refunded on a
prorated basis relative to the Warranty
Period remaining from the first date of
the claim.
NOTE: This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and,
if not installed and used in accordance with
the instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely
to cause harmful interference in which case the
user will be required to correct interference at his
own expense.
This Class A digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe A est
conforme à la norme NMB-003 du Canada.
www.autani.com
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hbs 300Hbs-dc

Table of Contents