Troubleshooting - STEINEL IS 3180 Manual

Hide thumbs Also See for IS 3180:
Table of Contents

Advertisement

Available languages

Available languages

IS 3180
IS 3360/
IS 3360 MX
Reaches
Basic
IS 3360
setting 1:
max. 20 m
max. 8-20 m
tangential;
tangential;
temperature
temperature
stabilised
stabilised
IS 3360 MX
Basic
max. 18 m;
setting 2:
temperature
max. 4-8 m;
stabilised
temperature
stabilised
+ precision
adjustment
+ precision
using shrouds
adjustment
by moving the
lens and Half-
round clip-on
shroud
Detection
7
11
levels
Switching zones 448
1416
Time setting
5 s - 15 min + pulse mode (approx. 2 s)
Twilight setting
2-1000 lux + teach mode
Manual override
selectable (4 h)
(permanent light)
IP rating
Surface-mounted: IP54 Concealed: IP20
Temperature
-20°C to +50°C
range:
*
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
IS 345
IS 345 MX
max. 20 x 4 m
max. 30 × 4 m
(tangential),
(radial) mounted
max. 12 x 4 m
at a height
(radial);
of 12 m;
temperature
temperature
stabilised
stabilised
+ precision
+ precision
adjustment
adjustment
using shrouds
using shrouds
5
5
280
120
34
11� Troubleshooting
Malfunction
Cause
No power at the sensor
n Fuse faulty, not
switched ON,
break in wiring
n Short circuit
Sensor will not switch ON
n Twilight setting set to
night-time mode during
daytime operation
n Bulb faulty
n Mains power switch
OFF
n Fuse faulty
n Detection zone not
properly targeted
Sensor will not switch OFF
n Continuous movement
in the detection zone
n Light being operated
is located in detection
zone and keeps switch-
ing ON as a result of
temperature change
n Light being operated
is in manual override
mode (LED ON)
Sensor keeps switching
n Light being operated is
ON/OFF
located in the detec-
tion zone
n Animals moving in the
detection zone
Sensor reach
n Change in ambient
change
temperatures
Remedy
n New fuse, turn ON
power switch, check
wiring with voltage tester
n Check connections
n Adjust setting
n Change bulb
n Switch ON
n Fit new fuse, check
connection if necessary
n Readjust
n Check zone, adjust or fit
shrouds if necessary
n Change detection zone
or fit shrouds
n Deactivate
manual override
n Change zone
or fit shrouds,
increase distance
n Change detection zone
or fit shrouds
n Use shrouds to define
detection zone precisely
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Is 3360 mxIs 345 mxIs 3360Is 345

Table of Contents