  • Page 1 STEINEL Vertrieb GmbH Dieselstraße 80-84 33442 Herzebrock-Clarholz Tel: +49/5245/448-188 www.steinel.de Contact www.steinel.de/contact Application Controller Information HF 3360...
  • Page 2 DE � � � � 12 Textteil beachten! GB � � � � 21 Follow written instructions! CZ � � � � 29 Dodržujte informace v textové části! SK � � � � 37 Dodržiavajte informácie v textovej časti! PL � � � � 45 Postępować...
  • Page 7: About This Document

    1� About this document – Please read carefully and keep in a safe place. – Under copyright. Reproduction either in whole or in part only with our consent. – Subject to change in the interest of technical progress. Symbols Hazard warning! Reference to other information in the document�...
  • Page 8: Electrical Installation

    Product components (Fig� 3�3) antee that the presence detector is also suitable for use in multi-master applications A Load module, power supply lead, surface-mounted with DALI 2 input devices for extending the detection zone. For further information in B Load module, power supply lead, concealed installation this regard, please refer to the Master/Slave section.
  • Page 9: Accessories (Optional)

    7� Accessories (optional) In addition to the daylight component, artificial light is also switched ON and OFF in relation to whether or not persons are present. User remote control RC 5 EAN Constant-lighting control can be activated / deactivated via RC 8 remote control and Additional functions RC 5 Smart Remote.
  • Page 10: Technical Specifications

    8� Operation / maintenance purchase in a safe place until the warranty period expires. STEINEL shall assume no liability for the costs or risks involved in returning a product. The sensor is suitable for switching on a light automatically. The unit is not suitable...
  • Page 11: Troubleshooting

    13� Troubleshooting Malfunction Cause Remedy No power at the sensor n Fuse faulty, n Replace fuse, turn ON not switched ON power switch, check lead with voltage tester n Short circuit n Check connections n Additional two-way n Switch ON switch OFF n Fuse faulty n New fuse, check...