Technical Specifications
Type of Ports for External
Antenna(s)
Output Power (Average)
Size of Fast Fourier Transform
(FFT) Channels
Type of Modulation
Type of Error Compensation
Dynamic Range (Receiver)
Dynamic Range (Transmitter)
Section 4.3

Operating Environment

The RUGGEDCOM WIN7025 can operate under the following environmental conditions:
Ambient Operating
a
Temperature
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure
b
Non-condensing
Section 4.4

Mechanical Specifications

Weight (Base Station)
Weight (Mounting Bracket)
Ingress Protection
Chassis Material
Section 4.5

Dimension Drawings

NOTE
All dimensions are in millimeters, unless otherwise stated.
32
N-Connect female, 50 Ω
2 x 36 dBm
1024/512FFT
QPSK, 16-QAM, 64-QAM
FEC Convolution Code, Turbo Code
-60 to 100 dBm
21 to 36 dBm
-40 to 65 °C (-40 to 149 °F)
-40 to 65 °C (-40 to 149 °F)
b
5% to 95%
2000 m (6562 ft)
15 kg (33 lbs)
6.5 kg (14 lbs)
IP67
Aluminum
RUGGEDCOM WIN7025
Installation Guide