Chapter 3
Technical Specifications
Output Power (Average)
Size of Fast Fourier Transform
(FFT) Channels
Type of Modulation
Type of Error Compensation
Dynamic Range (Receiver)
Dynamic Range (Transmitter)
Section 3.3

Operating Environment

The RUGGEDCOM WIN7018 can operate under the following environmental conditions:
Ambient Operating
Temperature
Ambient Relative Humidity
Ambient Storage Temperature
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure
b
Non-condensing
Section 3.4

Mechanical Specifications

Dimensions
Weight (Base Station)
Weight (Mounting Bracket)
Ingress Protection
Chassis Material
30
2 x 36 dBm
1024/512FFT
QPSK, 16-QAM, 64-QAM
FEC Convolution Code, Turbo Code
-60 to 100 dBm
21 to 36 dBm
-40 to 65 °C (-40 to 149 °F)
a
b
5% to 95%
-40 to 65 °C (-40 to 149 °F)
Refer to
Chapter 4, Dimension
15 kg (33 lbs)
6.5 kg (14 lbs)
IP67
Aluminum
Drawings.