Weatherproofing The Base Station - Siemens RUGGEDCOM WIN7025 Installation Manual

Hide thumbs Also See for RUGGEDCOM WIN7025:
Table of Contents

Advertisement

RUGGEDCOM WIN7025
Installation Guide
Figure 17: Connecting the Base Station in a Hazardous Location
1. Ethernet Switch    2. CAT-5e Cable    3. RUGGEDCOM WIN1212 Surge Suppression Unit    4. Base Station    5. DC Power Cable   
6. Power Supply Unit
2.
Connect the RUGGEDCOM WIN1212 surge suppression unit to the DC/ETH port on the base station.
3.
Connect a CAT-5e cable between the Ethernet switch and the RUGGEDCOM WIN1212 surge suppression unit.
IMPORTANT!
The AC power cable must meet the following specifications:
• Consist of 3 wires
• Minimum 18 AWG
• Less than 4.5 m (14.7 ft) long
• Safety certified according to national rules
4.
Connect the DC power cable to the power supply unit.
Section 2.9

Weatherproofing the Base Station

This section describes how to protect the base station from the ingress of harmful moisture, dirt and debris that
can lead to the premature failure of the device.
IMPORTANT!
The warranty is void if the base station is not properly weatherproofed.
CONTENTS
Section 2.9.1, "Securing the Sealing Screw"
Section 2.9.2, "Weatherproofing a Cable"
Weatherproofing the Base Station
2
1
3
2
5
6
Chapter 2
Installing the Base Station
4
25