Flowmeter Setup - Siemens SITRANS F US Protocol Manual

Clamp-on ultrasonic flowmeters
Hide thumbs Also See for SITRANS F US:
Table of Contents

Advertisement

On
Off
On
2.3

Flowmeter Setup

Note
The Flowmeter Setup procedure must be done to every channel of the meter.
In order for the Communications Module (P/N A5E31949269) to work properly, all of the
possible Logger configuration choices in the site setup must be correct.
Configure RS-232 Setup
In the [Meter Facilities] menu:
1. On the flowmeter keypad, press the <MENU> key.
2. Press <Left> arrow key until [Meter Type] appears then press <Down> arrow key to
[Meter Facilities].
3. Scroll to [RS-232 Setup] then press <Right> arrow key.
4. Set Baud: 9600
5. Set Parity: Odd
6. Set Data Bits: 7
7. Line Feed: NO
8. Network ID: 0
Configure Logger Setup
Note
This Logger Setup procedure must be done for both channels if it is configured as a dual
channel unit, or all channels, if a multi-channel unit. Refer to the Operation Instructions
manual for the FUS1010 flowmeter for menu details, if required.
1. On the flowmeter keypad, press the <MENU> key.
2. Press <Left> arrow key until [Meter Type] appears then press <Down> arrow key to
[Meter Facilities].
3. With [Meter Type] shown press <Right> arrow key until [Chan/Path Setup] appears.
4. Select [Channel 1] and the appropriate sensor type; we are setting up within the context
of the site setup that was created for this installation.
5. Use the <UP/DN> arrow keys and scroll to [Logger Setup]. Use the <Right> arrow key to
access the submenu.
6. Five menu choices will be shown. Since we have to check each one, the order in which
you change these is not important. Use the <UP/DN> arrow keys to select the main
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
On Off
On
Off
On
Off On
On
Off
On
Off On
On
Off
On
profile 44 5GN04-5.04.05 Dual Path: Clamp-On
profile 45 5GN05-5.04.05 Dual Path: Clamp-On
profile 46 5GN07-5.04.05 Quad Path: Clamp-On
Installing/Mounting
2.3 Flowmeter Setup
17

Advertisement

Table of Contents
loading

Table of Contents