6. Lubricate the tips of the quartz sleeve with clean water and insert new O-Ring. Ensure that the O-Ring makes
all-around contact with the cylinder pass-thru.
7. Tighten the compression nut while ensuring that the nut does not contact the quartz sleeve. Adjust O-Ring
position as necessary. The compression nut should be snug and tight, not over-torqued.
8. Repeat the previous two Steps 6 and 7 on the ballast-box compression nut.

Connect Plumbing

Important: Tube or hose ends must be cut squarely and cleanly, without rough edges. The quick-fit elbow
fitting has a C-clamp that will lock the tube in place, once inserted.
1. Insert the supply pipe into one (1) cylinder port and label the port "Inlet."
2. Insert the temporary pipe into the other cylinder port to direct water into a container.
3. Slowly fill the cylinder with water and flush cylinder for one (1) minute.
4. Remove temporary pipe and insert the return pipe into the cylinder port, then label the port "Outlet."
5. Slowly pressurize the UV unit by filling the cylinder with water while checking for leaks.
6. If leaks are found on the compression nuts, depressurize the unit and slightly tighten the leaking compression
nut.
7. Retest until a leak-free installation has been verified.
Once the UV unit is leak-free, the quartz sleeve installation is complete. The UV lamp can now be installed.
Note: To remove the tube from the fitting, first remove the C-clamp, then push the fitting sleeve downward.
Once the fitting sleeve is down, pull the tube out of the fitting.