Pump Electric Motor's normal-operating amperage plus the High Pressure Pump Electric Motor's
normal-operating amperage.
Voltage
(VAC)
120
230
100
220

Power Source Requirements

Check line voltage and frequency to ensure that it agrees with system nameplate. Grounding and circuit protection
should be done in accordance with National Electrical Code. See connection diagram on nameplate of motor or
refer to the diagrams within this manual.

Motor Rotation

Refer to Booster Pump and High Pressure Pump markings to determine proper rotation. For three-phase systems,
you may ensure proper rotation by jogging each motor from manual operation mode.

Electric Motor Specifications

Abbreviations:
• HP = Horse Power
• RPM = Revolutions Per Minute
• FLA = Full Load Amperes
• LRA = Locked Rotor Amperes at startup

Alternating Current Systems

Single Phase Alternating Current (Oil Filled Pumps)
VAC
Hz
110
50
220
50
115
60
230
60
Three Phase Alternating Current (Oil Filled Pumps)
VAC
Hz
220
50
380
50
230
60
460
60
30
Min. Voltage
(VAC)
108
207
90
198
High Pressure Pump Motor
HP
RPM
FLA
2
1450
21
2
1450
10.5
2.5
1750
21.2
2.5
1750
10.6
High Pressure Pump Motor
HP
RPM
FLA
1450
8.2
2.4
1450
2.4
4.1
2.4
1750
7.2
2.4
1750
3.6
Max. Voltage
Min. Power
(VAC)
132
253
110
242
LRA
HP
109
0.5
54.5
0.5
109
0.5
54.5
0.5
LRA
HP
30.9
0.5
15.45
0.5
30.9
0.5
15.45
0.5
Max. Power
(HZ)
(HZ)
58
62
58
62
48
52
48
52
Booster Pump Motor
RPM
FLA
2850
7.4
2850
3.7
3450
9.4
3450
4.7
Booster Pump Motor
RPM
FLA
2850
2.5
2850
1.5
3450
2.4
3450
1.2
Aqua Matic Compact 450-1800
LRA
20
10
20
10
LRA
8.2
4.7
7.9
3.9

Hide quick links: