Recommended Circuit Breaker Based on Operating Voltage
Operating Voltage
110-115 VAC
220-230 VAC
220 VAC
380 VAC
460 VAC
Recommended Power Wire Size to System
Operating Voltage
110-115 VAC
220-230 VAC
220 VAC
380 VAC
460 VAC
Recommended Power Wire Size to Booster Pump
Operating Voltage
110-115 VAC
220-230 VAC
220 VAC
380 VAC
460 VAC
Recommended Power Wire Size to High Pressure Pump
Operating Voltage
110-115 VAC
220-230 VAC
220 VAC
380 VAC
460 VAC
32
Phase
Max Load
(Amperes)
Single
34.8
Single
17.4
Three
10.4
Three
6.1
Three
5
Phase
Max Load
(Amperes)
Single
9.4
Single
4.7
Three
2.5
Three
1.5
Three
1.2
Phase
Max Load
(Amperes)
Single
25.5
Single
12.7
Three
7.9
Three
4.6
Three
3.8
Phase
Recommended Circuit Breaker (Ampere)
Single
50
Single
25
Three
15
Three
10
Three
10
Recommended Minimum Wire Size for Run Length
10 ft / 3 m
10 AWG / 6 mm²
12 AWG / 4 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
Recommended Minimum Wire Size for Run Length
10 ft / 3 m
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
Recommended Minimum Wire Size for Run Length
10 ft / 3 m
12 AWG / 4 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
25 ft / 8 m
50 ft / 15 m
8 AWG / 10 mm²
8 AWG / 10 mm²
12 AWG / 4 mm²
12 AWG / 4 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
25 ft / 8 m
50 ft / 15 m
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
16 AWG / 1.5 mm²
25 ft / 8 m
50 ft / 15 m
10 AWG / 6 mm²
10 AWG / 6 mm²
12 AWG / 4 mm²
12 AWG / 4 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²
14 AWG / 2.5 mm²