3.2.1

Configuring Active Input

This menu allows the user to configure a primary and backup input. In case there is an
input failover the MRD 7000 is capable of detecting the failed state and switching to a
secondary backup input in order to provide a continuous output. Which input is primary
and backup, how the inputs switchover and restore and switchover timing is all user
configurable. Input options include MPEG/IP Stream 1, MPEG/IP Stream 2, and Input
File.
Each MPEG/IP Stream input can be configured to use either Eth0 or Eth1 ports on the
back of the chassis.
Input File can play a stored .TS or .TRP transport stream file by uploading to the MRD
7000 internal storage. This is done by browsing to the MRD's IP address using FTP or
Windows file sharing.
Setting
Range
Primary Input
MPEG/IP Stream 1
MPEG/IP Stream 2
Input File
None
Backup Input
MPEG/IP Stream 1
MPEG/IP Stream 2
Input File
None
Switch On
Manual Only
TS Sync Loss
Page 18 (56)
MRD 7000 – User Manual
Active Input and Failover Configuration Menu
Description
Used for both normal operation and input
failover settings. During normal operation
this input will be the active input.
During failover operation this input will
become the active input. The catalyst for
what causes the unit to switch to this input
is configured in the following setting.
Manual Only: the unit will not switch inputs
automatically. The user must manually
switch inputs.