SPECIFICATIONS
Pressures
•
Max Static Pressure: 10 Bar.
•
Max Maintained Pressure: 5 Bar.
•
Min Maintained Pressure: (Gas Water Heater):
1.0 Bar (for optimum performance supplies
should be nominally equal).
•
Min Maintained Pressure (Gravity System):
0.1 Bar (0.1 bar = 1 Metre head from cold tank
base to showerhead outlet).
Note! 0.25 Bar when running both outlets.
Temperatures
•
Close temperature control is provided between
20°C and 50°C.
•
Optimum Thermostatic Control Range: 35°C
to 45°C (achieved with supplies of 15°C cold,
65°C hot and nominally equal pressures).
•
Recommended Hot Supply: 60°C to 65°C
(Note! The mixing valve can operate at
temperatures up to 85°C for short periods
without damage. However for safety reasons
it is recommended that the maximum hot water
temperature is limited to 65°C).
•
Minimum Differential between Hot Supply and
Outlet Temperature: 10°C.
•
Cold Water Range: 5°C - 25°C.
Thermostatic Shut-down
•
For safety the thermostat will shut off the
hot supply within 2 Seconds if the cold
supply fails (achieved only if the hot supply
temperature is greater than 10°C above the
set blend temperature).
Connections
•
Hot: Left (side nearest flow control), 15 mm
compression.
•
Cold: Right (side nearest temperature
control), 15 mm compression.
•
Outlet: top, 15 mm compression from diverter.
Note! This product does not allow for reversed
inlets and will deliver unstable temperatures if
fitted incorrectly.
Dimensions
59
Ø70
100 Min to Wall
190
Dimensions in mm
4
150
100 Min to Wall
340
80