MODEL 9000 ECONOMINDER
Time Brine Refill & Meter Setting Procedure (Cont'd.)
If we have 1000 gallons available from Step 3, we want to subtract the regeneration water used from the total water
available.
1000 gallons available - 55. gallons used = 945 gallons setting (in regeneration)
4. NOW set Meter wheel at approximately 950 gallons. Lift the inner dial of the meter program wheel so that you can
rotate it freely. Position the white dot opposite the 950 gallon setting (see diag. below).
NOTE: There is a slight delay time from the time the meter zero's out and when the cycle starts. Units using the 1/
15 rpm motor, 82 minute regeneration time available (tanks 6" thru 12") have a 9 minute delay . Units using
the 1/30 rpm motor, 180 minute regeneration time available (tanks 13" and larger) have an 18 minute
delay . Typically on residential equipment this delay period is not critical. On commercial applications, this
must be taken into consideration and continuous flows for 9 minutes or 18 minutes should be subtracted
from water available.
NOW
1. Insert Meter cable into Meter.
2. Check Bypass.
3. Plug unit in.