Download Print this page

Fleck 9000 Service Manual page 22

Econominder
Hide thumbs Also See for 9000:

Advertisement

MODEL 9000 ECONOMINDER
Service Instructions
PROBLEM
1.
Softener Fails To Regenerate.
2.
Hard Water.
3.
Unit Used Too Much Salt.
4.
Loss Of Water Pressure.
5.
Loss of Mineral Through Drain
Line.
6.
Iron In Conditioned Water.
7.
Excessive Water In Brine Tank.
Page 22
CAUSE
A. Electrical Service To Unit Has
Been Interrupted.
B. Timer Is Defective.
A. By-Pass Valve is Open.
B. No Salt in Brine Tank.
C. Injector Screen Plugged.
D. Insufficient Water Flowing Into
Brine Tank
E. Hot Water Tank Hardness.
F.
Leak At Distributor Tube.
G. Internal Valve Leak.
A. Improper Salt Setting.
B. Excessive Water in Brine Tank.
A. Iron Buildup In Line To Water
Conditioner.
B. Iron Buildup In Water
Conditioner.
C. Inlet of Control Plugged Due to
Foreign Material Broken Loose
From Pipes By Recent Work
Done On Plumbing System.
A. Air In Water System.
A. Fouled Mineral Bed.
A. Plugged Drain Line Flow
Control.
B. Plugged Injector System.
C. Timer Not Cycling.
Printed in U.S.A.
CORRECTION
A. Assure Permanent Electrical
Service (Check Fuse, Plug, Pull
Chain or Switch).
B. Replace Timer.
A. Close By-Pass Valve.
B. Add Salt To Brine Tank and
Maintain Salt Level Above Water
Level.
C. Clean Injector Screen.
D. Check Brine Tank Fill Time And
Clean Brine Line Flow Control If
Plugged.
E. Repeated Flushings Of The Hot
Water Tank is Required.
F.
Make Sure Distributor Tube Is
Not Cracked. Check O-Ring And
Tube Pilot.
G. Replace Seals and Spacers
And/Or Piston.
A. Check Salt Usage and Salt
Setting.
B. See Problem No. 7.
A. Clean Line To Water
Conditioner.
B. Clean Control and Add Mineral
Cleaner to Mineral Bed.
Increase Frequency of
Regeneration and/or Backwash
Time.
C. Remove Pistons and Clean
Control.
A. Assure That Well System Has
Proper Air Eliminator Control.
Check For Dry Well Condition.
A. Check Backwash, Brine Draw
And Brine Tank Fill. Increase
Frequency Of Regeneration.
A. Clean Flow Control.
B. Clean Injector and Screen.
C. Replace Timer.

Advertisement

loading