BURNER INSTALLATION
The EHASR, EHA, and EH oil burners were designed for furnaces, boilers, water heaters and a wide variety of
commercial applications ranging from pressure washers & asphalt trucks The burner is supplied as a completely
assembled unit. This burner should be installed into your appliance with the appliance manufacturer's recommendations;
if no recommendations are available it is up to the expertise of the installer.
NOTE: The burner must be installed in such a manner that all controls will be readily accessible for inspection, cleaning,
adjustment, and repairs.
INSTALLATION OF MOUNTING FLANGE
Position the mounting flange on the furnace wall, adjusting orientation as necessary until the bolt pattern of the appliance
allows the flange to sit flush. (See Figure 19 for flange dimensions.)
Note the orientation of the flange and remove it so that the flange gasket may be placed between the appliance wall and
flange. Tighten the flange to the furnace wall.
Insert the burner tube into the flange and position it per Figure 20 on page 30. Tighten the flange onto the burner tube.