Changing The Nozzles Of The Rapid, Semi-Rapid And Auxiliary Burners On The Cooktop; Changing Double Flame Burner Tips - V-ZUG GK11TGA Operating Instructions Manual

Table of Contents

Advertisement

Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Natural Gas
Burner
Hourly Gas
Consumption
(MJ)
Auxiliary
4,80
Semi-rapid
8,10
Rapid
11,60
Wok (inner)
22,00
Wok (outer)
Distanze "Z" 11
Before conversion the cooktop must be disconnected from the
electricity and gas valves must be turned to the OFF position.
Changing the nozzles of the rapid, semi-rapid
and auxiliary burners on the cooktop
Remove the pan supports, burner covers and diffusers.
1.
Change the nozzles using the spanner provided by our
2.
Service Centre (code 424699), taking special care to ensure
that the nozzle does not fall when it is removed from the
burner or when fitted.
Ensure that it is completely tightened in order to guarantee
the seal.
Note: it is not necessary to adjust the primary air control on
these burners.

Changing double flame burner tips

The glass panel and frame are fixed to the rest of the cooktop
using a clip mounting system. The following steps must be
taken to remove the glass panel and frame:
Remove all the burner covers and pan supports.
1.
Release the front clip fixing the appliance to the kitchen unit
2.
by removing the screw.
Loosen the screws on the burners and remove the control
3.
knobs from their respective housings.
6
Propane Gas
Injector
Hourly Gas
Injector
mark
Consumption
mark
(MJ)
97
3,50
53
130
6,00
70
157
8,50
83
65
47
20,00
215
115
12
Use the disassembly lever 483196 available from our Service
Centre. To release the front clips, apply the lever in the area
shown in figures below according to the cooktop model.
Never use the lever on glass edges which have no trim or
frame!
To release the rear clips, carefully raise the entire glass panel
and frame.
Changing the outer flame nozzle
Loosen the clamp screw to release the bushing by moving it
1.
backwards to access the main nozzle easily. Fig. a1.
Remove the outer flame nozzle by turning it towards the left.
2.
Fig. a2-a3.
Screw in the new outer flame nozzle. Fig. a3-a4.
3.
Adjust the distance of the airflow adjusting bushing L2
4.
according to the value -Z-. Fig. a5.
Tighten the clamp screw. Fig. a6.
5.
Changing the inner flame nozzle
Unscrew the part M3 from the threaded part M2; to do this,
1.
hold the threaded part in the opposite direction.
Remove the pipe from the part M2. Fig. b2.
2.
Disassemble the assembly of parts M2 and M4 from part M1.
3.
Fig. b3-b4.
Remove the inner flame nozzle M4 from part M2. Fig. b5-b6.
4.
Screw in the new inner flame nozzle M4. Fig. b6-b7.
5.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gk11tgGk51tpgGk51tpga

Table of Contents