4.
Connect the machine to the power source.
5.
Verify that the machine operates correctly by
pushing the ON button.
—When operating correctly, the dust collec-
tor runs smoothly with little or no vibration
or rubbing noises and both fluorescent
lamps will illuminate.
— Investigate and correct strange or unusual
noises or vibrations before operating the
machine further. Always disconnect the
machine from power when investigating or
correcting potential problems.
6.
Press the OFF button.
7.
Put on safety glasses, and connect the blast
cabinet to the air supply.
8.
Adjust the regulator knob to 120 PSI as
shown on the gauge.
-20-
9.
Close all doors, grasp the blast gun and
press the foot pedal. Air should exit from the
blast gun.
Note: If after this test, the regulator gauge
needle drops more than a few PSI when you
press the foot pedal, verify that the air supply
is not restricted. If setup correctly, the blast
gun media suction tube should draw 15-17
inches of mercury on a manometer.
10. Listen for air leaks, and use a solution of
warm water and dish soap on any areas
where possible leaks may be located. Correct
and reseal as required.
11. Adjust the air pressure down to 60 PSI and
disconnect the air supply and the electrical
power supply.