Seagate 77767496 Product Manual page 213

Fibre channel interface
Table of Contents

Advertisement

Table 132: Command Initiate Parameter Format
Bit
7
Byte
0
1
2
0
02h
3
Reserved
4
5
Field definitions (listed alphabetically)
Table
number
Parameter Code
132
80FFh
Command Initiate Port Code. This field identifies the port on the drive that receives the Log Sense command
and requested transfer of this page.
0 = Port A.
1 = Port B.
Table 133: Fibre Channel Link Format
Bit
7
Byte
0
1
2
0
3
4
5
6
7
Field definitions (listed alphabetically)
Table
number
Parameter Code
133
Code
Length
8100h
4 bytes
8101h
4 bytes
8104h
4 bytes
8105h
4 bytes
8106h
4 bytes
8107h
4 bytes
8108h
4 bytes
Fibre Channel Interface Manual, Rev. D
6
5
1
1
6
5
1
1
Description
Link Failure Count, Port A. Count of the number of Loss of Sync conditions that have occurred on
Port A which exceeded 100 msecs in duration.
Loss of Synchronization Count, Port A. Count of the number of short (< 100 msecs) Loss of Syn-
chronization conditions that have occurred on Port A.
Invalid Transmission Word Count, Port A. Count of the number of invalid transmission words/Run-
ning Disparity errors that have been detected on Port A.
Invalid CRC Count, Port A. Count of the number of write data frames that have been received
with invalid CRCs on port A. These errors are only detected when this drive is the target of the
data transfer.
LIP F7 Initiated Count, Port A. Count of the number of LIP F7s (Initialize LIP) which the drive has
initiated on Port A.
LIP F7 Received Count, Port A. Count of the number of LIP F7s (Initialize LIP) which the drive has
received on Port A.
LIP F8 Initiated Count, Port A. Count of the number of LIP F8s (Failure LIP) which the drive has
initiated on Port A.
4
3
Parameter Code (80FFh)
0
00
Reserved
4
3
Parameter Code
0
00
04h
Counter Data
2
1
1
CIP
2
1
1
0
1
0
1
199

Advertisement

Table of Contents
loading

Table of Contents