Table 121 summarizes the Log Select Command field settings used when updating the cumulative/threshold value settings
and the resulting action that will occur based on these field settings.
Table 121: Log Select Command field setting summary
PCR
PC
1
xx
0
11
0
10
0
01
0
00
The Log Select and Log Sense commands use the same log page format. See Section 12.10.
Fibre Channel Interface Manual, Rev. D
Parameter
List Length
All cumulative counter and threshold log page values will be set to "zero" on all
0
log pages.
All cumulative counter log page values will be set to "zero" on all log pages.
0
All threshold log page values will be set to "zero" on all log pages.
0
The cumulative counter for a specific parameter code will be set to the stipu-
nn
lated value on a specified log page as found in the Log Parameter Page data.
The threshold for a specific parameter code will be set to the stipulated value
nn
on a specified log page as found in the Log Parameter Page data.
Resulting action