Current And Deferred Errors - Seagate 77767496 Product Manual

Fibre channel interface
Table of Contents

Advertisement

Table 93:
Error codes for bytes 12 and 13 of sense data (values are in hexadecimal) (Continued)
Byte 12
Byte 13
Description
(ASC)
(ASCQ)
55
01
XOR cache is not available
55
03
Insufficient reservation resources
55
04
Insufficient registration resources
5B
00
Log exception
5B
01
Threshold condition met
5B
02
Log parameter value at maximum
5C
00
Servo RPL status change
5C
01
Servo RPL spindles synchronized
5C
02
Servo RPL spindles not synchronized
5D
00
Failure prediction threshold exceeded
5D
FF
False failure prediction threshold exceeded
65
00
Voltage fault
80
00
General firmware error qualifier
80
80
FC FIFO error during read transfer
80
81
FC FIFO error during write transfer
80
82
Disc FIFO error during read transfer
80
83
Disc FIFO error during write transfer
80
84
LBA seeded CRC error on read
80
85
LBA seeded CRC error on write
80
86
IOEDC error on read
80
87
IOEDC error on write
81
00
Reassign power-fail recovery failed
11.5.1.2

Current and deferred errors

Error code 70h (current error) indicates that the Check Condition or Command Terminated status returned is
the result of an error or exception condition on the command that returned the Check Condition or Command
Terminated. This includes errors generated during execution of the command by the actual execution process.
It also includes errors not related to any command that are first observed during execution of a command.
Examples of this latter type of error include disc servo-mechanism off-track errors and power-up test errors.
Error code 71h (deferred error) indicates that the Check Condition status returned is the result of an error or
exception condition that occurred during execution of a previous command for which Good status has already
been returned. Such commands are associated with use of the Immediate bit (start unit), with some forms of
caching, and with multiple command buffering.
The deferred error is indicated by returning Check Condition status to the appropriate initiator as described
below. The subsequent execution of a Request Sense command returns the deferred error sense information.
If Check Condition status for a deferred error is returned, the current command has not performed any storage
operations or output operations to the media. After the target detects a deferred error condition on a logical
unit, it returns a deferred error according to the rules described below:
1. If a deferred error can be recovered with no external system intervention, a deferred error indication is not
Fibre Channel Interface Manual, Rev. D
153