Raypak XTherm 1005A Installation And Operation Manual page 42

Type h, wh, and p
Hide thumbs Also See for XTherm 1005A:
Table of Contents

Advertisement

Item
Application
TARGET
H MODE 1, 2, 3
TANK SETP
WH
TANK DIFF
WH
POOL SETP
P
POOL DIFF
P
MODE
H MODE 1, 2, 3
SETPOINT
H MODE 1, 2, 3
OUT START
H MODE 1, 2, 3
OUT DESIGN
H MODE 1, 2, 3
Boil START
H MODE 1, 2, 3
Boil DESIGN
H MODE 1, 2, 3
TARGET MAX
H MODE 1, 2, 3
TARGET MIN
H MODE 1, 2, 3
TARGET DIFF
H MODE 1, 2, 3
IND SENSOR
H MODE 1, 2, 3
DHW DIFF
H MODE 2, 3
IND SUPPLY
H MODE 2, 3
DHW PRIORITY
H MODE 2
PRI OVR
H MODE 2, 3
SYS PURGE
All
MIX TYPE
H / WH / P MIX
MIX TARGET
H / WH / P MIX
MIX LOCK
H / WH / P MIX
MIX TRIM
H / WH / P MIX
MIX SPEED
H / WH / P MIX
MIX INV
H / WH / P MIX
WWSD
H MODE 1,2,3
UNITS
All
MODBUS
All
ADDRESS
All
DATA TYPE
All
BAUD RATE
All
PARITY
All
* Maximum operator dial setting.
42
Range
RSET <> SETP
OFF, 50°F to 150°F (10°C to 66°C)
2°F to 10°F (1°C to 5°C)
50°F to 104°F, 106°F (10°C to 41°C)
1°F to 5°F (0.5°C to 3°C)
1,2,3
50°F to 220°F (10°C to 104°C)
35°F to 85°F (2°C to 29°C)
-60°F to 45°F (-51°C to 7°C)
35°F to 150°F (2°C to 66°C)
70°F to 200°F (21°C to 93°C)
100°F (38°C) to PIM value*
OFF, 50°F to 190°F (10°C to 88°C)
2°F to 42°F (1°C to 24°C)
OFF <> ON
2°F to 10°F (°1C to 5°C)
OFF, 50°F (10°C) to PIM value*
OFF <> ON
Au, 0:10hr to 2:00hr
OFF, 0:20min to 20:00min
H (VALVE, PUMP, PLNT)
WH (1 <> 2)
50°F to 104°F (10°C to 40°C)
ON <> OFF
-5 to 5
FAST <> MED <> SLOW
ON <> OFF
40°F to 100°F (4°C to 38°C)
deg F <> deg C
OFF <> MNTR <>
TEMP <> RATE
1 to 247
RTU <> ASCI
2400 <> 9600 <> 19K2 <>
57K6 <> 115K
NONE <> EVEN <> ODD
Table T.
Description
RSET = Outdoor Reset, SETP =Setpoint
Tank set point temperature
Tank Differential temperature
Pool setpoint temperature
Pool differential temperature
Piping and application configuration.
Boiler target temperature while a heat demand is
present for setpoint operation
Outdoor starting temperature - outdoor reset
Outdoor design temperature - outdoor reset
Starting boiler target temperature when the outdoor
temperature is at outdoor start outdoor reset
Design boiler target temperature when the outdoor
temperature is at outdoor design outdoor reset
Maximum target system temperature
Minimum target system temperature
Differential for target system temperature
Selects whether a DHW sensor is used for indirect
DHW tank
Differential for the target indirect DHW tank
temperature, requires IND Sensor = ON
Target boiler temperature for the DHW heat
exchanger during indirect DHW operation, requires
IND Sensor = OFF
Selects whether or not Indirect DHW priority is active
during indirect DHW operation
Sets the length of the indirect DHW priority override
time
Sets the length of the system pump post purge
Selects the type of control depending on pipe
configuration for CWP
Inlet target temperature
The equipment will trigger a warning when "MIX
Target" is not reached within 7 minutes. MIX LOCK =
ON; Alarm and lockout, MIX LOCK = OFF; Alarm only
This adjustment is for various types and sizes of units
as well as various actuator motor speeds and types
supplied by Raypak
This setting defines speed of response
This option is related to the use of spring return
actuators with a proportional valve
The system warm weather shutdown temperature
outdoor reset, requires TARGET = RSET
Show units using icons in display
ModBus Operating Mode: Off, Monitor, Temp Control,
Rate Control
ModBus slave address
Modbus data type
Setup/Adjust Menu
Default
SETP
125°F (52°C)
3
80°F (27°C)
2°F (1°C)
1
180°F (82°C)
70°F (21°C)
10°F (5°C)
70°F (21°C)
180°F (82°C)
220°F (104°C)
50°F (10°C)
10°F (5°C)
OFF
6°F (4°C)
180°F (82°C)
OFF
1:00hr
20 seconds
H VALVE
WH 2
120°F (49°C)
OFF
0
MED
OFF
70°F (21°C)
deg F
MNTR
1
RTU
19K2
EVEN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xtherm 1505aXtherm 2005a