5. MAINTENANCE

The owner can perform the 2-month inspections, but the 6-month
inspections must be performed by a Qualified Technician. Contact your
Authorized Dealer
Units installed in adverse environments will require additional
maintenance on a monthly basis.
IMPORTANT: Please test the phone in your elevator during every maintenance.
If the phone is inactive, please shut down the elevator until the phone line is
active. This applies to all lifts in a hoistway or enclosure models

Maintenance Schedule

Verification by owner
Verify general operation of the Telecab17
Verify operation of the safety devices:
• Underpan sensors (safety switches)
• Floor plug sensors (safety switches)
• Door contact
• Door lock
• Emergency stop
Verification by technician
Verify operation of the emergency lowering system
Verify operation of the safety brake
Check the safety components:
• Chains
• Chain connecting links
• Chain pulleys and shafts
• Parts holding the chains on the roller supports
• Chain tensioners on the rail (ensure they are tight)
• Cylinder head (cotter pins, cracks, welds)
• Hydraulic system (check for leaks)
• Fastening devices (check for looseness)
• Up relays – verify that one of the two up relays is not stuck
in the activated position. Use a multimeter to verify that
every normally-open contact is open when the relays are
not being activated.
Check the rollers (function and wear)
Check for oil leaks
Telecab17 Owner's Manual
NOTE
.
Frequency
Every 2 months
Every 2 months
Frequency
Every 6 months
Every 6 months
Every 6 months
Every 6 months
Every 6 months
Part No. 001081, 28-m08-2018