4. SAFETY FEATURES

Safety Underpan and Floor
Plug Sensors
The safety underpan (Figure 4) is
located under the Telecab17 platform.
The underpan has sensors that detect
any obstacles and stop the downward
travel of the lift.
The floor plug sensors (Figure 4) are
located on top of the Telecab17 and will
stop the upward travel of the elevator if
an obstacle that weighs more than 20 lb
(9.1 kg) is detected on the floor plug.
Door Lock and Open Door
Sensor
The WR-500 lock keeps the cab door locked when the Telecab17 is operating or
not at a landing.
The door open sensor prevents the Telecab17 from moving when the cab door
is open.
Emergency Door Opening
The cab door can be opened using the
emergency key provided (note that two
identical emergency keys are
provided).
To open the door in an emergency
situation, insert the key into the hole of
the WR-500 lock (Figure 5) and turn it.
Note that the key is for emergency use only and should be stored in a safe place.
After use of any emergency function (access key or manual lowering
device), ensure that all doors/gates are secure and locked. While the
emergency function is in use, DO NOT leave the area unattended.